1171 SureLock Wood Flooring Adhesive
-
Excellent
Initial Grab
-
High
Early Strength
Development
-
Excellent
Ultimate Bond
Strength & Elongation
-
Enhanced
Moisture &
Alkali Resistance
-
Solvent-Free & Low
Odor
|
|
|
|
| Typical
Use: |
Traffic
Type: |
| Installs
engineered wood plank and wood parquet flooring. |
N/A |
| Bonds: |
Bonds
To: |
| Wood
parquet up to 5/16” thick and engineered
wood plank up to 9/16” thick and 4.5” wide.
Do not use to install stair nose or reducers. |
Concrete,
underlayments, wood substrates, terrazzo and existing
resilient on all grade levels as recommended by
the flooring manufacturer. |
| Warranty: |
| HENRY's Best 10 Year Warranty |
Back
to Top
|
TECHNICAL
DATA
| Base: |
Latex |
| Color: |
Light
Yellow |
| Taggant
Color: |
Yellow/Orange |
| Next
Generation: |
Yes |
| Open
Time: |
None;
NOTE: works best with a few minutes of open time |
| Working
Time: |
30
minutes; NOTE: Working times vary due to temperature
and humidity |
| Size: |
4
Gallon |
| Shipping
Unit: |
1
pail |
| Weight
Per Gallon: |
11.7
lbs |
| Quantity
Per Pallet: |
48
pails |
| Shelf
Life: |
One
year if not opened |
| Freeze-Thaw
Stable: |
To
10°F (-12°C) Avoid low temperatures or
multiple freeze/thaw cycles |
| VOC's: |
1
g/L; calculated and reported, SCAQMD 1168 |
| UPC
Information: |
0-81833-00030-6 |
Back
to Top
INSTALLATION
INSTRUCTIONS
|
DIRECTIONS:
- Read
installation instructions and MSDS thoroughly
prior to installation.
- All
surfaces must be sound, smooth, dry, clean,
free of excess moisture and alkali. Remove
dirt, wax, loose paint and all foreign matter
that would interfere with a good bond, such
as curing agents and sealers. Condition the
area to be installed, adhesive and flooring
at 65°F (18°C) or above for 48 hours
before, during and 48 hours after installation.
- Refer
to the wood flooring manufacturer’s
specific recommendations for subfloor preparations.
- Always
run a calcium chloride and alkali test over
concrete on any grade level. For accurate
results, curing agents must be removed in
areas where tests will be run. Moisture test
results should meet the flooring manufacturer’s
recommendations, but should not exceed 3
bs./1000 sq.ft/24 hrs., as determined by
the calcium chloride moisture test (ASTM-F
-1869). Alkali readings should be 5 to 9.
INSTALLATION
TIPS:
- Stir
any liquid on the surface into the adhesive
and full spread adhesive using recommended
trowel.
- Before
installing floor, allow adhesive to set open
a few minutes.Do
not spread more adhesive than can be covered
within 30 minutes.
- Do
not allow a heavy film to form on the surface
of the adhesive. If the adhesive dries or
skins over, the adhesive must be scraped
and fresh adhesive needs to be applied.
- Press
wood flooring down firmly, lifting a piece
occasionally to be sure the adhesive is fully
bonding to the backing.
- Allow
1/2” space around perimeter of room
and stationary objects for normal wood flooring
expansion.
- Roll
floor with a heavy roller, if recommended
by the wood flooring manufacturer. Adhesive
must set overnight before exposing to traffic
or applying finish.
CLEANUP:
- Wet
Adhesive: Clean,
white cloth dampened with soapy water.
- Dried
Adhesive: Clean,
white cloth dampened with mineral spirits;
carefully following warnings on the container.
WARNINGS:
Carefully read and follow all cautions and warnings on the product
label. Refer to the Material
Safety Data Sheet for additional product information. |
Back