ARDEX Worldwide
 
   
 

Find the right system & calculate how much you need
 

Find more
ARDEX
products
 

Find more
W.W. Henry
products

 

 


Product InfoTechnical Data
Installation Instructions MSDS

HENRY GreenLine® GL33
High-Performance VCT Adhesive

  • 97% lower in emissions than current Carpet and Rug Institute (CRI) criteria
  • Almost No Discernible Odor
  • Antimicrobial Product Protection
  • Hypoallergenic
  • Superior Bond Integrity
  • Excellent Trowelability
  • HENRY's Best 10-Year Warranty

 

PRODUCT INFORMATION

Typical Use: Traffic Type:

For installing vinyl composition tile (VCT) requiring a low emitting, low odor, high-performance adhesive.

All
Bonds: Bonds To:
Vinyl composition tile (VCT). Suspended A.P.A. approved wood underlayment boards, terrazzo, well bonded resilient flooring on all grades, cementitious underlayments and dry concrete. NOTE: Should not be used over perimeter bonded or cushion backed resilient sheet flooring or over tile below grade.
Warranty:
HENRY's Best 10 Year Warranty

Back to Top

TECHNICAL DATA

Base: Filled latex
Color: Off-white paste
Taggant Color: Yellow/Orange
Ultra Green : Yes
Open Time: Dry to touch - 20 to 60 minutes
Working Time: 24 hours
Size: 4 Gallons
Shipping Unit: Pail
Weight Per Gallon: 10.20 lbs.
Quantity Per Pallet: 48 Pails
Shelf Life: 12 months if not opened
Freeze-Thaw Stable: Keep from freezing, store between 40F-100F
UPC Information: 4 Gallon: 0 81833 00002 3 

Back to Top

INSTALLATION INSTRUCTIONS

PREPARATION:

  • Read installation instructions and MSDS thoroughly prior to installation.
  • All surfaces must be sound, smooth, dry, clean and free of excessive moisture or alkali. Remove dirt, wax, loose paint and all other foreign matter that would interfere with a good bond, such as curing agents and sealers. Condition the area to be installed, adhesive and flooring at 65°F (18°C) or above for 48 hours before, during and 48 hours after installation.
  • Refer to VCT manufacturer’s specific recommendations for subfloor preparation.
  • Always run a calcium chloride and alkali test over concrete on any grade level. For accurate results, curing agents must be removed in areas where tests will be run. Moisture test results should meet the flooring manufacturer’s recommendations, but should not exceed 5 lbs./1000 sq.ft/24 hrs. as determined by the calcium chloride moisture test (ASTM-F-1869). Alkali readings should be 5 to 9.

INSTALLATION:

  • Stir any liquid on the surface into the adhesive and full spread using the recommended trowel notching.
  • Allow adhesive to set open until dry to the touch, approximately 20-60 minutes. When dry to the touch, the adhesive will be tacky with no transfer to the fingers.
  • Install and fit all tiles within 24 hours. Working time will vary based on job conditions, substrate, temperature and humidity.
  • Roll floor with a 100 lb. roller if recommended by the tile manufacturer.
  • Do not wet wash or strip tile for five days after installation.
  • Always follow VCT manufacturer’s recommendations for maintenance procedures to minimize any risk of improper maintenance interfering with the adhesive bond.
  • As with any installation process, adequate ventilation of the work area should be maintained. Persons who are sensitive to odors and/or chemicals should avoid the
    work area.

CLEANUP:

  • Wet Adhesive: Clean, white cloth dampened with soapy water.
  • Dried Adhesive: Clean, white cloth dampened with mineral spirits; carefully following warnings on container.

WARNINGS:
Carefully read and follow all cautions and warnings on the product label. Refer to the Material Safety Data Sheet for additional product information.